
timeit is the tool everybody reaches for and the one every warning is attached to. The
warnings tend to be about the statistic — best of five is not what your users get — and that
turns out to be the smallest of the distortions it introduces. The largest one is not a
statistical choice at all. It is a line in the method body.
>>> import inspect, timeit
>>> print(inspect.getsource(timeit.Timer.timeit))
Inside Timer.timeit, before the loop runs: gcold = gc.isenabled() and then gc.disable().
Unconditionally, with no argument to turn it off. Every number timeit has ever reported was
taken with the cycle collector switched off.
What the collector is worth
Two implementations of the same job. Both allocate 120,000 objects; one leaves them in reference cycles the counter cannot free, the other does not:
$ python3 experiments/evalloop/timeitmethod.py
python 3.13.2 on darwin
best of 9 everywhere unless the column says otherwise
what turning the collector off is worth
workload gc disabled gc enabled ratio
cyclic garbage 5.3 ms 11.0 ms 2.07x
no cycles 5.5 ms 5.4 ms 0.99x
timeit.Timer.timeit calls gc.disable() before the loop and restores it after,
so every number it reports is from the left column.
which statistic the tools hand back
within one process, 9 rounds
best 627.0 ns what the CLI prints
median 630.6 ns
worst 631.5 ns
spread 1.01x
across 9 processes, each reporting its own best
best 618.4 ns
median 623.9 ns
worst 635.2 ns
spread 1.03x
the shape the loop leaves the call site in
four objects, one class 9.21 ns a read
four objects, four classes 13.34 ns a read
polymorphic costs 1.45x
Read the first block as a comparison rather than as two numbers. With the collector off — which
is the only column timeit can produce — the cyclic implementation is the faster of the two,
5.3 ms against 5.5. With the collector on, it is 11.0 against 5.4, which is 2.07x slower.
The ranking inverts. Not the margin, the winner. And the workload that inverts it is not exotic: two objects that point at each other is what a parent-child relationship, a doubly linked list, a cached back-reference and most ORM row objects look like in memory.
The second workload is the control. It allocates the same number of objects and makes no
cycles, and the collector costs it nothing measurable — 5.5 against 5.4, inside the noise. So
the effect is not “the collector is slow”, it is “the collector charges for cycles”, and
timeit never charges for them.
The shape the loop leaves behind
The third block is the second distortion. A timeit loop executes one statement over the same
objects several million times, which is precisely the condition the specialising interpreter is
built for: an instruction that keeps seeing one class gets rewritten into a variant that assumes
that class. Which variant a read gets
is visible in the disassembly, and it is not the instruction
the compiler emitted.
Four objects of one class, read in a loop, cost 9.21 ns a read. Four objects of four classes, same loop, same attribute, cost 13.34 — 1.45x. Nothing about the attribute changed; the call site stopped being able to assume.
A benchmark of two implementations is usually written with one concrete class each, so both
sides get the specialised path. Production code that dispatches over a base class, or over
anything with subclasses, gets the other one. The ratio between the two implementations may
survive that, and it may not — the point is that timeit cannot tell you, because it only ever
runs the left-hand case.
The distortion that was not there
The statistic block is the one that did not produce a finding, and that is worth publishing too. Best, median and worst inside one process spanned 1%. Nine separate processes, each reporting its own best, spanned 3%.
At that size the choice between best and mean does not change a decision. Whatever is wrong
with a timeit comparison on this machine, it is not the statistic — and the effort spent
arguing about which one to quote would be better spent on the two blocks above it.
That number belongs to this machine on this day: idle, on mains power, nothing else running. On a shared runner it is the first thing that grows. The way to know is to run the harness there.
The method this leaves
Three checks before a timeit result is worth publishing. They are the same three a profile
needs, for the same reason: an instrument with a fixed per-call
cost is only safe on calls large enough to absorb it.
Does the workload create reference cycles? If it might, time it with perf_counter and the
collector in the state the real program has, calling gc.collect() between rounds so each one
starts level.
Does the call site see one type in the benchmark and several in production? If so, the benchmark is measuring the specialised path and the program is not.
And say which statistic the number is. Not because the choice matters much — the block above says it did not here — but because a number without that label cannot be compared with anyone else’s.
None of this makes timeit the wrong tool. It makes it a tool with a domain: two
implementations of the same shape, allocating nothing that participates in a cycle, called
through a site that sees one type in production as well as in the loop. Inside that domain its
numbers are as good as its reputation. The failure is not the tool reporting the wrong number;
it is a reader taking a number from inside that domain and using it outside.
Where to stop
One machine, macOS on Apple silicon, CPython 3.13.2, idle. Every figure is the best of nine rounds, and the across-process block is nine separate interpreters.
The collector figure is for a workload built to make cycles at a high rate. A program that
creates a cycle occasionally will see a smaller number, and one that never creates one will see
the control row: no difference at all. Nothing here measures generational thresholds or what
gc.freeze does to any of it.
Frequently asked
Should I stop using timeit?
No. Use it for what it is good at, which is comparing two implementations of the same shape that allocate nothing interesting. The two cases to check first are whether the workload creates reference cycles and whether the call site sees more than one type in production. If neither is true, the timeit number and the real number agree.
How do I keep the collector on?
Do not use timeit for that measurement. There is no argument for it — the disable call is unconditional inside Timer.timeit. Time the workload with perf_counter around it, call gc.collect() before each round so the state is the same, and leave the collector in whatever state the calling program would have.
Why does the monomorphic loop measure something different?
Because the interpreter specialises the instruction to the shape it keeps seeing. A LOAD_ATTR that has only ever seen one class becomes a variant that assumes that class; one that sees four falls back to the generic instruction. A timeit loop over one type reaches a state that a call site handling four subclasses never reaches.
Is the 3% spread a property of timeit?
No, it is a property of this machine on the day. It was idle, on mains power, with nothing else running. On a loaded machine or a shared runner the spread is the number that grows, and the way to find out is to run the same harness there rather than to assume either result.
Where this came from
Run it yourself — every figure above came out of these:
- evalloop/timeitmethod.py — What timeit's gc.disable() is worth, and the shape its loop leaves


